{"title":"Long Range Switches","description":"","products":[{"product_id":"vis-lrpoe4-2n-4-port-poe-switch-with-2-uplink-ports","title":"VIS-LRPOE4-2N: Long Range Switches","description":"\u003cp class=\"p1\"\u003e\u003cstrong\u003e4-Port PoE Switch, 60W, With 2 Uplink Ports, 100 MBPS Ports, UL Listed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\" data-mce-style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003eFeatures\u003c\/strong\u003e\u003cspan style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\" data-mce-style=\"font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 0.875rem;\"\u003e \u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e6 x 100Mbps network ports (RJ45), including 4 PoE ports\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMultiple working modes to address your business needs: Normal, Secure and Surveillance\u003c\/li\u003e\n\u003cli\u003eSupport port traffic control\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for secure mode, all downlink ports can communicate only with uplink ports\u003c\/li\u003e\n\u003cli\u003eUp to 820 ft transmission distance on surveillance mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport buffer optimization\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAll metal housing, safe and reliable\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/info.invidtech.com\/compliant\" data-mce-href=\"https:\/\/info.invidtech.com\/compliant\"\u003eNDAA Compliant Product-Learn More Here.\u003c\/a\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecs\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"t1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td1\"\u003e\n\u003ch4 class=\"p1\"\u003eModel\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td2\"\u003e\n\u003ch4 class=\"p1\"\u003eVIS-LRPOE4-2N\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePorts\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e6×100Mbps network ports (RJ45), including 4 PoE ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eStandards\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eIEEE802.3,IEEE802.3u,IEEE802.3az,IEEE802.3x,IEEE802.3af,IEEE802.3at\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eSwitching\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ecapacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e1.2Gbps\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eForwarding\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eperformance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e0.90Mpps\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePacket Buffer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e448Kbit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eMAC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e1K\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eDimensions\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e(W×D×H)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e4.3 x 3.9 x 1 in (108*100*25.5mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e.4 lb (0.19KG)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePower supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eDC: 48\/51V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e802.3at\/af (4\/5+, 7\/8-)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eMax. PoE Power\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eMax capacity: 60W\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eMax capacity for single\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eport: 30W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePrior Ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e1 ~ 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eCooling Fans\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e0\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eOperating\u003c\/p\u003e\n\u003cp class=\"p1\"\u003etemperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e32°F ~ 104°F\u003cspan class=\"Apple-converted-space\"\u003e  \u003c\/span\u003e(0°C-40°C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eOperating\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ehumidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e10% ~ 90% (noncondensing)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eStorage\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ehumidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e5% ~ 90% (noncondensing)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" valign=\"top\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eIndicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003ePOWER:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: AC input is normal\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: No AC input\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eNo PoE Indicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003ePoE-MAX:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: The POE power supply power of the whole machine is less than 80% of the specification\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: The POE power supply power of the whole machine is greater than 85% of the specification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eLINK\/ACT:\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: No link\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: Linked\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eFlashing: Transmitting data\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eWorking\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eMode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eDefault(Normal mode) : All ports can communicate witheach other.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eEXTEND(Surveillance mode): Transmission distance up to 250 meters.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eUL: A6156, E496771\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eOrdering\u003c\/h5\u003e\n\u003cp\u003e\u003cb\u003eVIS-LRPOE4-2N: \u003c\/b\u003e4-Port PoE Switch with 2 Uplink Ports\u003c\/p\u003e\n\u003ch5\u003eDownloads\/Support\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/info.invidtech.com\/hubfs\/AAA_SpecSheets\/Vision\/Accessories\/VIS-LRPOE4-2N.pdf\"\u003e\u003cspan\u003eSpec Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVision Products \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca title=\"Vision Products Support Page\" href=\"http:\/\/info.invidtech.com\/dc-vision\" target=\"_blank\" data-mce-href=\"http:\/\/info.invidtech.com\/dc-vision\"\u003eSupport Page\u003c\/a\u003e\u003c\/p\u003e","brand":"Vision Series","offers":[{"title":"Default Title","offer_id":42696763179248,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2618\/4954\/files\/VIS-LRPOE4-2N_3000.jpg?v=1718808660"},{"product_id":"vis-lrpoe8-2an-8-port-poe-switch-with-2-uplink-ports","title":"VIS-LRPOE8-2AN: Long Range Switches","description":"\u003cp class=\"p1\"\u003e\u003cstrong\u003e8-Port PoE Switch, 88W, With 2 Uplink Ports, 100 MBPS Ports, UL Listed\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e10 x 100Mbps network ports (RJ45), including 8 PoE ports\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMultiple working modes to address your business needs:Normal, Secure and Surveillance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport port traffic control\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for secure mode, all downlink ports can communicate only with uplink ports\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUp to 820 ft transmission distance on surveillance mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport buffer optimization\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAll metal housing, safe and reliable\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/info.invidtech.com\/compliant\" data-mce-href=\"https:\/\/info.invidtech.com\/compliant\"\u003eNDAA Compliant Product-Learn More Here.\u003c\/a\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecs\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"t1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td1\"\u003e\n\u003ch4 class=\"p1\"\u003eModel\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td2\"\u003e\n\u003ch4 class=\"p1\"\u003eVIS-LRPOE8-2AN\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePorts\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e10×100Mbps network ports (RJ45), including 8 PoE ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eStandards\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eIEEE802.3,IEEE802.3u,IEEE802.3az,IEEE802.3x,IEEE802.3af,IEEE802.3at\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eSwitching\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ecapacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e2Gbps\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eForwarding\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eperformance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e1.49Mpps\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePacket Buffer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e448Kbit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eMAC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e1K\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eDimensions\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e(W×D×H)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e6.7\u003cspan class=\"Apple-converted-space\"\u003e  \u003c\/span\u003ex 4 x 1 in (171*101*25.5mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e.64 lb (0.29KG)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePower supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eDC: 48\/51V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e802.3at\/af (4\/5+, 7\/8-)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eMax. PoE\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ePower\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eMax capacity: 88W\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eMax capacity for single port: 30W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePrior Ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e1 ~ 2\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eCooling Fans\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e0\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eOperating\u003c\/p\u003e\n\u003cp class=\"p1\"\u003etemperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e32°F ~ 104°F\u003cspan class=\"Apple-converted-space\"\u003e  \u003c\/span\u003e(0°C-40°C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eOperating\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ehumidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e10% ~ 90% (noncondensing)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eStorage\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ehumidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e5% ~ 90% (noncondensing)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" valign=\"top\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eIndicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003ePOWER:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: AC input is normal\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: No AC input\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eNo PoE Indicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003ePoE-MAX:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: The POE power supply power of the whole machine\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eis less than 80% of the specification\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: The POE power supply power of the whole machine\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003eis greater than 85% of the specification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eLINK\/ACT:\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: No link\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: Linked\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eFlashing: Transmitting data\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eWorking\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eMode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eDefault (Normal mode): All ports can communicate witheach other\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eEXTEND (Surveillance mode): Transmission distance up to 250 meters\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eUL: A6152, E496771\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eOrdering\u003c\/h5\u003e\n\u003cp\u003e\u003cb\u003eVIS-LRPOE8-2AN: \u003c\/b\u003e8-Port PoE Switch with 2 Uplink Ports\u003c\/p\u003e\n\u003ch5\u003eDownloads\/Support\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/info.invidtech.com\/hubfs\/AAA_SpecSheets\/Vision\/Accessories\/VIS-LRPOE8-2AN.pdf\" data-mce-href=\"https:\/\/info.invidtech.com\/hubfs\/AAA_SpecSheets\/Vision\/Accessories\/VIS-LRPOE8-2AN.pdf\"\u003e\u003cspan\u003eSpec Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVision Products \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca href=\"http:\/\/info.invidtech.com\/dc-vision\" title=\"Vision Products Support Page\" data-mce-href=\"http:\/\/info.invidtech.com\/dc-vision\" target=\"_blank\"\u003eSupport Page\u003c\/a\u003e\u003c\/p\u003e","brand":"Vision Series","offers":[{"title":"Default Title","offer_id":42696785920240,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2618\/4954\/files\/VIS-LRPOE8-2AN_3000.jpg?v=1718808907"},{"product_id":"vis-lrpoe16-2an-16-port-poe-switch-with-2-uplink-ports","title":"VIS-LRPOE16-2AN: Long Range Switches","description":"\u003cp class=\"p1\"\u003e\u003cstrong\u003e16-Port PoE Switch, 1X SFP, 225W, UL Listed, With 2 Uplink Gig Ports, 100 MBPS Ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e16 x 100Mbps PoE ports (RJ45)+ 1 x 1000Mbps Gigaethernet ports +1 x 1000Mbps Combo ports\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMultiple working modes to address your business needs:  Normal, Secure and Surveillance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport port traffic control\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for secure mode, all downlink ports can communicate only with uplink ports\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUp to 820 ft transmission distance on surveillance mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport buffer optimization\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAll metal housing, safe and reliable\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/info.invidtech.com\/compliant\"\u003eNDAA Compliant Product-Learn More Here.\u003c\/a\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecs\u003c\/h5\u003e\n\u003ctable class=\"t1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"td1\" valign=\"middle\"\u003e\n\u003ch4 class=\"p1\"\u003eModel\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td2\" valign=\"middle\"\u003e\n\u003ch4 class=\"p1\"\u003eVIS-LRPOE16-2AN\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003ePorts\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e16×100Mbps PoE ports (RJ45)+ 1×1000Mbps Gigaethernet ports +1×1000Mbps Combo ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eStandards\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eIEEE802.3,IEEE802.3u,IEEE802.3z,IEEE802.3ab,IEEE802.3x,\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eI EEE802.3af,IEEE802.3at,IEEE802.3az\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eSwitching\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ecapacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e7.2Gbps\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eForwarding\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eperformance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e5.36Mpps\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003ePacket Buffer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e4Mbit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eMAC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e16K\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eDimensions\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e(W×D×H)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e17.3 x 7.5 x 1.7 in (440*189.8*44mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e4.7 lb (2.12KG)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003ePower supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eAC: 100-240V, 50\/60Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e802.3at\/af (4\/5+, 7\/8-)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eMax. PoE\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ePower\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eMax capacity: 225W\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eMax capacity for single port: 30W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003ePrior Ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e1 ~ 8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eCooling Fans\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eOperating\u003c\/p\u003e\n\u003cp class=\"p1\"\u003etemperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e32°F ~ 104°F\u003cspan class=\"Apple-converted-space\"\u003e  \u003c\/span\u003e(0°C-40°C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eOperating\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ehumidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e10% ~ 90% (noncondensing)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eStorage\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ehumidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003e5% ~ 90% (noncondensing)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"top\" rowspan=\"4\"\u003e\n\u003cp class=\"p1\"\u003eIndicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003ePOWER:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: AC input is normal\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: No AC input\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003ePoE:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: No PoE power supply\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: PoE power supply is normal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003ePoE-MAX:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: The POE power supply power of the whole machine is less than 80% of the specification\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: The POE power supply power of the whole machine is greater than 85% of the specification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eLINK\/ACT:\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: No link\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: Linked\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eFlashing: Transmitting data\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eWorking\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eMode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eDefaul t (Normal mode) : All ports can communicate with each other\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eVLAN (Secure mode): Downlink ports can communicate only with uplink ports.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eEnabling PD keepalive function, the switch will restart the IPC via PoE power when the IPC\u003c\/p\u003e\n\u003cp class=\"p1\"\u003esends no message in a period of time.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eExtend(Surveillance mode): Transmission distance up to 250 meters. Downlink ports can communicate only with uplink ports.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"td3\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"td4\" valign=\"middle\"\u003e\n\u003cp class=\"p1\"\u003eUL: A6157, E496771\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eOrdering\u003c\/h5\u003e\n\u003cp\u003e\u003cb\u003eVIS-LRPOE16-2AN: \u003c\/b\u003e16-Port PoE Switch with 2 Uplink Ports\u003c\/p\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003ch5\u003eDownloads\/Support\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/info.invidtech.com\/hubfs\/AAA_SpecSheets\/Vision\/Accessories\/VIS-LRPOE16-2AN.pdf\"\u003e\u003cspan\u003eSpec Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVision Products \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca href=\"http:\/\/info.invidtech.com\/dc-vision\" title=\"Vision Products Support Page\" target=\"_blank\"\u003eSupport Page\u003c\/a\u003e\u003c\/p\u003e","brand":"Vision Series","offers":[{"title":"Default Title","offer_id":42696791916784,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2618\/4954\/files\/VIS-LRPOE16-2AN_3000.jpg?v=1704469841"},{"product_id":"vis-lrpoe24-2an-24-port-poe-switch-with-2-uplink-ports","title":"VIS-LRPOE24-2AN: Long Range Switches","description":"\u003cp class=\"p1\"\u003e\u003cstrong\u003e24-Port PoE Switch, 1X SFP,\u003cspan class=\"Apple-converted-space\"\u003e  \u003c\/span\u003e370W, UL Listed, With 2 Uplink Gig Ports, 100 MBPS Ports\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e24 x 100Mbps PoE ports (RJ45) + 1 x 1000Mbps Gigaethernet ports +1 x 1000Mbps Combo ports\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMultiple working modes to address your business needs: Normal, Secure and Surveillance\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport port traffic control\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport for secure mode, all downlink ports can communicate only with uplink ports\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eUp to 820 ft transmission distance on surveillance mode\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupport buffer optimization\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAll metal housing, safe and reliable\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/info.invidtech.com\/compliant\" data-mce-href=\"https:\/\/info.invidtech.com\/compliant\"\u003eNDAA Compliant Product-Learn More Here.\u003c\/a\u003e\u003c\/h2\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ch5\u003eSpecs\u003c\/h5\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\" class=\"t1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td1\"\u003e\n\u003ch4 class=\"p1\"\u003eModel\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td2\"\u003e\n\u003ch4 class=\"p1\"\u003eVIS-LRPOE24-2AN\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePorts\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e24×100Mbps PoE ports (RJ45) + 1×1000Mbps Gigaethernet ports +1×1000Mbps Combo ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eStandards\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eIEEE802.3,IEEE802.3u,IEEE802.3z,IEEE802.3ab,IEEE802.3x,\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eI EEE802.3af,IEEE802.3at,IEEE802.3az\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eSwitching\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ecapacity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e8.8Gbps\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eForwarding\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eperformance\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e6.55Mpps\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePacket Buffer\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e4Mbit\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eMAC\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e16K\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eDimensions\u003c\/p\u003e\n\u003cp class=\"p1\"\u003e(W×D×H)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e17.3 x 9.6 x 1.7 in (440* 244.8 *44mm)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eWeight\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e6.5 lb (2.93KG)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePower supply\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eAC: 100-240V, 50\/60Hz\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePoE\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e802.3at\/af (4\/5+, 7\/8-)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eMax. PoE\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ePower\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eMax capacity: 370W\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eMax capacity for single port: 30W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003ePrior Ports\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e1 ~ 8\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eCooling Fans\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e1\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eOperating\u003c\/p\u003e\n\u003cp class=\"p1\"\u003etemperature\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e32°F ~ 104°F\u003cspan class=\"Apple-converted-space\"\u003e  \u003c\/span\u003e(0°C-40°C)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eOperating\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ehumidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e10% ~ 90% (noncondensing)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eStorage\u003c\/p\u003e\n\u003cp class=\"p1\"\u003ehumidity\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003e5% ~ 90% (noncondensing)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"4\" valign=\"top\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eIndicator\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003ePOWER:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: AC input is normal\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: No AC input\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003ePoE:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: No PoE power supply\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: PoE power supply is normal\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003ePoE-MAX:\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: The POE power supply power of the whole machine is less than 80% of the specification\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: The POE power supply power of the whole machine is greater than 85% of the specification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eLINK\/ACT:\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eOff: No link\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eSteady on: Linked\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eFlashing: Transmitting data\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eWorking\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eMode\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eDefaul t(Normal mode) : All ports can communicate with each other\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eVLAN (Secure mode): Downlink ports can communicate only with uplink ports.\u003cspan class=\"Apple-converted-space\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eEnabling PD keepalive function, the switch will restart the IPC via PoE power when the IPC\u003c\/p\u003e\n\u003cp class=\"p1\"\u003esends no message in a period of time.\u003c\/p\u003e\n\u003cp class=\"p1\"\u003eExtend(Surveillance mode): Transmission distance up to 250 meters. Downlink ports can communicate only with uplink ports.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"middle\" class=\"td3\"\u003e\n\u003cp class=\"p1\"\u003eCertification\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"middle\" class=\"td4\"\u003e\n\u003cp class=\"p1\"\u003eUL: A6158, E496771\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003eOrdering\u003c\/h5\u003e\n\u003cp\u003e\u003cb\u003eVIS-LRPOE24-2AN: \u003c\/b\u003e24-Port PoE Switch with 2 Uplink Ports\u003c\/p\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ch5\u003eDownloads\/Support\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/info.invidtech.com\/hubfs\/AAA_SpecSheets\/Vision\/Accessories\/VIS-LRPOE24-2AN.pdf\"\u003e\u003cspan\u003eSpec Sheet\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVision Products \u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003ca title=\"Vision Products Support Page\" href=\"http:\/\/info.invidtech.com\/dc-vision\" target=\"_blank\"\u003eSupport Page\u003c\/a\u003e\u003c\/p\u003e\n\u003cdiv\u003e\u003c\/div\u003e","brand":"Vision Series","offers":[{"title":"Default Title","offer_id":42696796307696,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/2618\/4954\/products\/VIS-LRPOE24-2AN_3000.jpg?v=1649967500"}],"url":"https:\/\/invidtech.com\/collections\/long-range-switches\/compliance_ndaa-compliant.oembed","provider":"Invidtech","version":"1.0","type":"link"}